Scope of Roofing by Roofer

  • 1 vapour retardant
  • 1 optional vapour retardant termination
  • 2 primary insulation
  • 3 secondary insulation
  • 4 fibre cant strip
  • 5 primary membrane and membrane protection
  • 6 membrane flashing
  • 7 membrane base flashing
  • 8 metal counter flashing with optional galvanized steel fixation bar
  • 9 accepted sealant

Suggested Details by Others

  • A accepted deck
  • B air/vapour seal