Flashing Details: Base and Counter Flashing with Reglet

Detail 5: Base and Counter Flashing with Reglet

Scope of Roofing by Roofer

  • 1 vapour retardant
  • 1 optional vapour retardant termination
  • 2 primary insulation
  • 3 secondary insulation
  • 4 fiber cant strip
  • 5 primary membrane and membrane protection
  • 6 membrane flashing
  • 7 metal base flashing
  • 8 metal counter flashing with sealant

Suggested Details by Others

  • A accepted deck
  • B air/vapour seal
  • C reglet opening