ARCA logo

Serving Alberta's Roofing Industry Since 1961

ARCA logo

Flashing Details: Through Wall Scupper with Hopper

Detail 15: Through Wall Scupper with Hopper

Scope of Roofing by Roofer

  • 1 vapour retardant
  • 1 optional vapour retardant termination
  • 2 primary insulation
  • 3 secondary insulation
  • 4 fiber cant strip
  • 5 primary membrane and membrane protection
  • 6 metal scupper with hopper
  • 7 membrane flashing
  • 8 metal base flashing
  • 9 metal counter flashing with sealant

Suggested Details by Others

  • A accepted deck
  • B air/vapour seal